********************************************************************** Media Pro 4000 Brief Date: January 21st 2000 File: Media_Pro_4000_Power_BR012100.txt Module: PSM-4010, APS-40ES30, MP4000 Modules Title: Power Load, Efficiency, Dissipation, Agency Approvals ********************************************************************** 1) PSM-4010 Specifications (used in VMR-4000) a) Input, Voltage & Frequency Auto Switching 1) 90 VAC to 135 VAC 2) 175 VAC to 264 VAC 3) 47 HZ to 63 HZ b) Input, Power 1) 2.5 A @ 90 VAC @ 80 Watt Load c) Input, Inrush Surge Current 1) 45 A peek d) Efficiency 1) 73% @ 115 VAC @ 80 Watt Load e) Heat Dissipation 1) Approximately 21.6 Watts a) {80 watts * 27%} f) Operating Temperature 1) 0 to +50 Deg C @ 80 Watts g) Internal Power supply {Power One MAP80-4001} Agency Approvals 1) UL a) 478 (5th Edition) b) 1950 / UL 1950(D3) 2) TUV a) IEC 380 b) IEC 950 c) VDE 0805 d) VDE 0806 e) VDE 0871 (level B) f) EN60950 3) CSA a) C22.2 #950 b) 1402 (C) 4) FCC a) 47CFR15J (level B) 5) CE a) EN55022 (Conducted Class B) b) EN55022 (Radiated Class B) c) EN61000-4-2 (ESD Level 4, 8KV) d) EN61000-4-3 (Radiated Level 3, 10v/M) e) EN61000-4-4 (EFT/B Level 3) 2) APS-40ES30 Specifications (used on HMR-4000, APC-4010/20, ICM-4010/20) a) Input, Voltage & Frequency Auto Switching 1) 90 VAC to 260 VAC 2) 47 HZ to 63 HZ b) Input, Power 1) 0.6 A @ 120 VAC, 60 Hz @ 40 Watt Load c) Input, Inrush Surge Current 1) 20 A peek d) Efficiency 1) 70% @ 115 VAC @ 40 Watt Load e) Heat Dissipation 1) Approximately 12 Watts a) {40 watts * 30%} f) Operating Temperature 1) 0 to +40 Deg C @ 40 Watts g) Agency Approvals 1) UL Listed a) 5T18 b) 1950 2) TUV Licensed a) IEC 950 b) EN60950 c) EN55022 (Class B) 3) CSA Certified a) C22.2 #234 b) C22.2 #950 4) FCC a) Part 15, Class B 5) Other a) CE b) VFG234 (Class B) c) IEC 801-2 (ESD Level 3) d) IEC 801-4 (EFT Level 3) 3) Power Load, and Heat Dissipation Greatly Depend on External Loads, use and duty cycle. 4) Modules (ABM, AOM, ASM, DSM, ICM, IOM, LCM, SEM, TCM, IMC) a) Internal Supplied Power Load 1) (ABM, AOM, ASM, IOM, TCM) a) Less than 2 watts Quiescent 2) (DSM, ICM, LCM, SEM, IMC) a) Less than 4 watts Quiescent a) External Supplied Power Load 1) (ABM, DSM, ICM, LCM, SEM, TCM) a) negligible 2) (AOM, ASM, IOM, IMC) {Power Output Modules) a) Less than 0.5 watts Quiescent b) Typically less than 24 watts (Depends on external Loads) 1) ASM example Approximately 8 Watts a) (8) 100ma Valves @ +/- 10VDC 2) IOM example Approximately 144 Watts a) (6) bits on, with 1A loads b) Heat Dissipated approximately 0.3W per bit ---------------------------------------------------------------------- Specifications subject to change at any time. The data in this document incorporates proprietary rights of Anitech Systems Inc., 25021 Anza Drive, Valencia, CA 91355 USA Phone (661) 257-2184 Fax (661) 257-2025 Email Mail@Anitech-Systems.com Web http://www.Anitech-Systems.com Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others, without the consent of ANITECH SYSTEMS.