Media Pro 4000 Brief Date: August 13th 2015 File: MSC-4400_Environmental_Technical_Specification_BR081215 Module: MSC-4400 (Media Show Controller 4400 series) Optional Mounting Brackets: RM-4400, RMFP-4400; RMP-4400 Title: MSC-4400 Environmental Technical Specifications ********************************************************************* This brief is intended for Control Engineers and Technicians who are installing, programming or maintaining a MediaPro Control System. It is assumed that you have some understanding of Show Control, Windows PCs, and have some experience with MediaPro 4000 Systems. 1) Power Supply Requirements A) MSC Power, 5 to 12 Watts depending on Options and Applications 1) Nominal Voltage 9 to 24VDC 2) Some MSC I/O Modules may require additional Field Power a) e.g. Optional IOM-4410s require additional Field I/O Power B) Provided Wall Warts: 9VDC Nominal 1) V-INFINITY (CUI) 3A-181WP09 / EMS090200-P5P-SZ In: 100 to 240VAC @ 0.6A, 50 to 60Hz Out: 9VDC @ 2.0A 2) CUI DMS090110-P5P-IC, In: 120 to 240VAC @ 0.4A, 47 to 63Hz Out: 9VDC @ 1.1A 2) Environmental Conditions Information A) 10° to 32° C (40° - 90° F) Recommended Operating Temperature B) -40° to 60° C (-4° - 140° F) Storage Temperature C) 0 to 95% (Without Condensation) Relative Humidity D) To ensure that your equipment has the longest life possible, it should be placed in an area with good ventilation, low humidity, out of direct sunlight, and away from heat sources or lamps. 1) Never expose equipment to moisture of any sort. 2) Always maintain a dust, dirt and smoke free environment. 3) Always remember that high temperature is the enemy of all electronic equipment. 3) MSC-4400 Approximate Physical Dimensions A) One Half EIA Standard RETMA Nineteen inch Rack Mount 1) Height 1 3/4in (1 RU) 2) Width 8 3/4in (1/2 RU) 3) Depth 8 1/2in B) Overall Installed Depth up to 15in (Table Top or Rack Mounted) 1) Nominal MSC Overall Outside Depth 8 1/2in a) 2in to 4 1/2in Additional Clearance Depth behind MSC, Necessary for Cables connecting to the back of the MSC 2) 1/8in, Minimum clearance in Front of Rack Mount Surface a) 1 1/2in to 2in clearance in Front for EtherNet or Serial Cable, or to insert / remove Compact Flash Card C) Rack Mounting Tray (RM-4400), Width 19in (1 RU) 1) Rack Mount Tray Filler Plate (RMFP-4400), {8 3/4in Wide x 1 45/64in High x 1 1/4in Deep}, when only one MSC is installed on the Rack Mount Tray D) Panel Mounting Angle Brackets (RMP-4400) {pair} 1) Nominal MSC Overall Outside Width on Panel 11 to 11 3/8in a) 2 5/8in Width added to MSC Width 8 3/4in (1/2 RU) by a Pair of Panel Mounting Angle Brackets (RMP-4400) {Ears 1 1/8 to 1 5/16in Wide x 8 5/16in Long} 2) Vertical Panel Mounting Height up to 15in {Front Panel facing upwards} a) Nominal MSC Overall Outside Height on Panel 8 1/2in; 2in to 4 1/2in Additional Clearance Height below MSC Necessary for Cables connecting to the back of the MSC b) 1/8in, Minimum clearance Above MSC Top {Front Panel}; 1 1/2in to 2in clearance Above MSC for EtherNet Cable, Serial Cable, or to insert / remove Compact Flash Card