Media Pro 4000 Brief Date: October 25th 2005 File: ICM_Beeper_BrOct252005.txt Module: ICM-4020/20E/30, MSC-4400 Title: ICM Beeper / Annunciator ********************************************************************* This brief is intended for Control Engineers and Technicians who are installing, programming or maintaining a MediaPro Control System. It is assumed that you have some understanding of Show Control, Windows PCs, and have some experience programming MediaPro 4000 Systems. THE BEEPER The beeper on the ICM4020 has been made available for users by means of this cue statement: SET @Rxx,17,0 AUDIO ff ; The xx implies that the command can be used to activate the beeper in any rack. The duration of the beep is specified in frames (at 30/s) by the number ff. Using the command with ff=0 before the timer expires will immediately stop the beep. The number ff is valid from 0 to 255, for a maximum beeper time of just over 8 seconds. Entries larger than this will be curtailed by the ICM to the maximum value of 255. e.g. Set @r0,17,0 Audio 1; Rack 0 ICM beeps Set @r1,17,0 Audio 1; Rack 1 ICM beeps --------------------------------------------------------------------- Specifications subject to change at any time. The data in this document incorporates proprietary rights of Anitech Systems Inc. 25021 Anza Drive, Valencia, CA 91355 USA (661)257-2184ph (661)257-2025fax Email Support@Anitech-Systems.com Web http://www.Anitech-Systems.com FTP ftp://ftp.Anitech-Systems.com Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others, without the consent of ANITECH SYSTEMS.