********************************************************************** Media Pro 4000 Brief Date: November 6th 1998 File: IBM_Think_Pad_380ED_Evaluation_BR110698.txt Module: MP4000, AP4000 Software Title: Evaluation of IBM Think Pad 380ED for use with MP4000 Software. ********************************************************************** 1) Serial Port on Rear Panel of Laptop: a) The default configuration of the Serial Port was disabled. 1) To enable the serial port perform the following steps a) Start Menu Control Panel System Device Manager Ports (Com & LPT) Communications Port 2 (Com 2) 1) Communications Port 2 (Com 2): Properties General Device Usage Section a) Device Usage Section: UN-CHECK BOX, Disable in Hardware Profile 2) Close All Windows/Dialogs (OK). 1) Shut Down PC 2) Re-Boot PC. b) Now the MP4000 software should communicate with an ICM via the Serial Port. 2) Parallel Port on Rear Panel of Laptop: a) The BIOS configuration of this laptop uses the Alternate Parallel Port Addressing b) To enable the MP4000 Software to use the parallel port perform the following steps 1) The MP4000 Software needs to be configured for the alternate address a) OPTIONS Communications LPT1: 3BC. c) Now the MP400 software should communicate with an ICM via the Parallel Port d) The Laptops default configuration of LPT1: 3BC, bi-directional is ok. 3) Notes a) The Normal Addresses are: LPT1: 378, LPT2:278, LPT3: 3BC b) The ThinkPad Laptop's addresses are: LPT1: 3BC, LPT2: 378, LPT3: 278 c) The ThinkPad's BIOS setting for the parallel port can be checked by running an MS-DOS prompt 1) and typing PS2 ? Parallel ---------------------------------------------------------------------- Specifications subject to change at any time. The data in this document incorporates proprietary rights of Anitech Systems Inc., 25021 Anza Drive, Valencia, CA 91355 USA Phone (805) 257-2184 Fax (805) 257-2025 Phone (661) 257-2184 Fax (661) 257-2025 Email Mail@Anitech-Systems.com Web http://www.Anitech-Systems.com Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others, without the consent of ANITECH SYSTEMS.